AD2079 Troubleshooting B-1
Appendix B: Troubleshooting
Problem Check List
✘ No power to keyboard !
!!
! Check AC outlet
!
!!
! Check wall transformer connections
!
!!
! Check modular cable connections to keyboard
and terminal block.
!
!!
! Measure transformer output at terminal block.
✘ No response to keystrokes (power verified) !
!!
! Check connection of terminal block to system
controller's communication port.
!
!!
! Check baud rates for keyboard and system
controller.
!
!!
! Check DIP switch setting for communications
protocol.
!
!!
! Run built-in test to verify keyboard operation.
✘ Keyboard responds to keystrokes on some, but
not all keys.
!
!!
! Verify keyswitch position. With the keyswitch
in the OPERATE position, the OFF, ARM, and
PROG keys are disabled.
!
!!
! Run built-in test to verify keyboard operation.
✘ Cannot perform menu positioning with dual
function section keys
!
!!
! Verify keyswitch position. Switch must be in
MENU position to perform menu
programming functions.
✘ Display LEDs not visible. !
!!
! Verify LEDs brightness level.
!
!!
! Run built-in test to verify LED operation.
!
!!
! Re-initialize firmware
✗ Keyboard speaker not audible. !
!!
! Verify speaker volume level.
!
!!
! Check that switching system controller has not
disabled speaker.
!
!!
! Run built-in test to verify speaker operation.
✘ Cannot set up baud rate, brightness level, or
speaker volume.
!
!!
! Verify that keyswitch is in MENU position.
✘ Cannot access main menus of system CPU. !
!!
! Verify that keyswitch is in MENU position.
!
!!
! Verify that correct monitor is selected for
menu programming.
!
!!
! Verify CPU program monitor output is
connected
✘ Pan/tilt cameras move continuously and/or
cursor scrolls continuously in MENU mode.
!
!!
! Run built-in test to verify joystick operation.